Industrial Steam Boilers

Coal-Biomass-Internal Furnace | 60-300 BHP Boiler

Fully Wet Back | Three-Pass | Internal Furnace | Top Automatic Fuel Feeding Steam Boiler Capacity: 1,000 kg/hr to 5,000 kg/hr

Avlon’s FireMax – FMM Series is a high-performance, compact, multi-fuel steam boiler designed for industrial applications requiring efficiency, automation, and installation convenience. Featuring a fully wet-back, three-pass internal furnace configuration, this packaged system achieves up to 84% net thermal efficiency. It is ideal for industries needing flexible fuel options and minimal on-site installation. The FMM Series comes fully equipped with all standard boiler accessories, including ash chutes, flue gas outlets, insulation with aluminum cladding, lifting lugs, and maintenance access ports—making it a plug-and-play solution tailored for the Philippine industrial environment.

The automated top fuel feeding system ensures uniform combustion with high thermal output. Fuel is introduced from a bunker above the boiler, pulled into the system via high-velocity air from a forced draft fan, and delivered using customizable mechanisms such as gravity-fed gates, screw conveyors, and moving floors. Primary and secondary airflows are precisely balanced to ensure complete combustion, circular flame motion, and prevention of clinker formation. The MK4 chain grate stoker, grit arrestor, induced and forced draft fans, and TDS control system form part of the complete package to ensure smooth operation and superior combustion control.

Price : 3,000,000 - 10,000,000 PHP

Request a customized quote based on your specific requirements. Share your details, and our team will get back to you with the best pricing and solution.

Request a Quote

Machine Capacity & Specifications

Parameters
Max. Steam Output (F&A 100°C)kg/h100015002000300040005000
Boiler Design CodeASMEASMEASMEASMEASMEASME
Design Pressurekg/cm217.517.517.517.517.517.5
Pressure (Safety Valve set Pr.)kg/cm217.517.517.517.517.517.5
Temperature°C208208208208208208
Heating Surface Aream235.5256.2169.45111.99152.55190.8125
Water Holding Capacitym32.535.1575.5378.57811.05213.738
Steam Holding Capacitym30.660.9881.2711.6962.3252.975
Steam / Water Interface Aream23.0944.5014.9816.5177.138.92575
Dryness Fraction0.970.970.970.970.970.97
Flue Gas Temperatures (At Boiler Outlet)°C290290290290290290
Flue Gas Temperatures (At HRU Outlet)°C210210210210210210
Material Of Construction (Shell)SA515/516 GR.70SA515/516 GR.70SA515/516 GR.70SA515/516 GR.70SA515/516 GR.70SA515/516 GR.70
Material Of Construction (Tubes)ERW-BS 3059ERW-BS 3059ERW-BS 3059ERW-BS 3059ERW-BS 3059ERW-BS 3059
Dry Weight Of BoilerTons6.3828.31910.22814.73521.30925.6
BOILER GRATE, FUEL & EFFICIENCY
Type Of GrateSpecial Fire GratesSpecial Fire GratesSpecial Fire GratesSpecial Fire GratesSpecial Fire GratesSpecial Fire Grates
Grate Aream21.411.882.083.654.445.24
No. of FurnaceONEONEONEONEONEONE
Fuel
Efficiency (Without Heat Recovery Unit)%747474747474
Efficiency (With Heat Recovery Unit)828282828282
BOILER CONNECTIONS & FITTINGS
Main Steam Stop Valve Sizemm40508080100100
Steam Safety Valve Sizemm252525252525
Quantitynos222222
Blow Down Valve Sizemm404040404040
Level Control Blow Down Size /Qtymm / nos15 X 115 X 115 X 115 X 115 X 115 X 1
Water Level Gauge Glass (Size / Qty)mm / nos20 X 220 X 220 X 220 X 220 X 220 X 2
Centre To Centre Distancemm400400400400400400
Drain Cock (Size)mm151515151515
Stop Valve In Feed Line (Size / Qty)mm / nos25 X 325 X 325 X 325 X 340 X 340 X 3
NRV In Feed Line (Size / Qty)mm / nos25 X 325 X 325 X 325 X 340 X 340 X 3
Air Vent Valve (Size / Qty)mm / nos25 X 125 X 125 X 125 X 125 X 125 X 1
Mobrey Isolation Stop Valve (Size / Qty)mm / nos25 X 225 X 225 X 225 X 225 X 225 X 2
Stop Valve For Insp. Gauge (Size)mm151515151515
BOILER ACCESSORIES
Feed water pump TypeMultistage PumpMultistage PumpMultistage PumpMultistage PumpMultistage PumpMultistage Pump
Feed water pump Capacitym3/h1.52.52.54.64.67.666666667
Feed water pump Headmlc200200200200200200
Feed water pump Motorhp1.533444
Induced Draft Fan TypeBackward-InclinedBackward-InclinedBackward-InclinedBackward-InclinedBackward-InclinedBackward-Inclined
Induced Draft Fan Flowm3/min75110150225300375
Induced Draft Fan Head @ 280°CmmWC190190190190190190
Induced Draft Fan Motor Horse Powerhp7.51012.5152025
Forced draft fan TypeBackward-InclinedBackward-InclinedBackward-InclinedBackward-InclinedBackward-InclinedBackward-Inclined
Forced draft fan Flowm3/min355070100135185
Forced draft fan Head @ 20°CmmWC100100100100100100
Forced draft fan Motor Horse Powerhp23357.58
BOILER DIMENTIONS
Shell Outside Diametermm165020002150260029503250
Shell Lengthmm250031803180366040104310
Tube Outside Diametermm63.563.563.563.563.563.5
Thicknessmm3.43.43.43.43.43.4
Lengthmm395044504480500046005300
Widthmm340035904170436053006000
Heightmm340036003900430046505350

Our Technology

Explore Avlon Inc’s comprehensive range of energy and environmental equipment, engineered to deliver reliable performance, operational efficiency, and sustainable industrial solutions across diverse applications.

Key Features

Multi Fuel
Multi Fuel
Economical Fuel
Economical Fuel
Robust Design
Robust Design
High Efficiency
High Efficiency
Industrial Steam
Industrial Steam

Reach Out to Us

Connect with our experts to discuss your project requirements & discover customized environmental and engineering solutions tailored to your needs.

Download Catalogue

Explore our complete range of products and solutions, including detailed specifications & features designed to meet diverse industry.

Solutions Within...!! Delivering Clean Water, Clean Air, & Reliable Energy Solutions

Connect with Avlon Inc for reliable energy and environmental engineering solutions designed to improve efficiency, ensure compliance, and support your long-term growth.

Request a Consultation

My Cart