Industrial Steam Boilers

Coal-Biomass-High Pressure | 2500-6000 BHP Boiler

Bi-Drum | Corner Tube | High-Pressure Power Plant Boiler
Capacity: 32,000 kg/hr to 100,000 kg/hr

Avlon’s FireMax – FMP Series is a high-performance power plant-grade steam boiler engineered with a single drum, corner tube, membrane wall design—ideal for high-pressure, high-temperature applications. This advanced configuration eliminates bottom drums and reduces thermal stress, offering superior durability and operational safety. The elevated drum position and compact circulation path enable rapid startup, high steam purity, and fast response to load variations. Its self-supporting, earthquake-resistant structure ensures reliability in demanding environments. With high thermal efficiency, reduced maintenance needs, and unmatched responsiveness, the FMP Series is purpose-built for continuous, high-load industrial operations and steam turbine applications.

This design features direct in-bed fuel feeding, allowing for seamless combustion of a wide range of solid fuels. Enhanced heat recovery is achieved through a pressurized economizer and air pre-heater, while larger membrane wall tube spacing improves heat transfer and accessibility for maintenance. Steam quality is further enhanced by primary and secondary internal steam purifiers, ensuring long turbine life and consistent process efficiency. Membrane wall cooling eliminates refractory, further extending boiler life and reducing downtime.

Price : 10,000,000 - 60,000,000 PHP

Request a customized quote based on your specific requirements. Share your details, and our team will get back to you with the best pricing and solution.

Request a Quote

Machine Capacity & Specifications

MODEL NOPACKMAX -0.1VPACKMAX -0.2VPACKMAX -0.3VPACKMAX -0.4VPACKMAX -0.5VPACKMAX -0.6VPACKMAX -0.9V
Boiler OrientationVertical , Coil TypeVertical , Coil TypeVertical , Coil TypeVertical , Coil TypeVertical , Coil TypeVertical , Coil TypeVertical , Coil Type
Boiler TypeWater TubeWater TubeWater TubeWater TubeWater TubeWater TubeWater Tube
No of passes in the BoilerThree PassesThree PassesThree PassesThree PassesThree PassesThree PassesThree Passes
Boiler Design CodeASMEASMEASMEASMEASMEASMEASME
BOILER OPERATIONAL FEATURES
Operation ModeFully AutomaticFully AutomaticFully AutomaticFully AutomaticFully AutomaticFully AutomaticFully Automatic
Control SystemTwo StageTwo StageTwo StageTwo StageTwo StageTwo StageTwo Stage
Load ControllerSeparate PIDSeparate PIDSeparate PIDSeparate PIDSeparate PIDSeparate PIDSeparate PID
O2 Monitoring and controlManualManualManualManualManualManualManual
CO Monitoring and ControlManualManualManualManualManualManualManual
BOILER CAPACITY & SPECIFICATION
Rated Steam Output F & A 100 0 Ckg / hr100200300400500600850
Design Pressure (Max)kg / cm2(g)10.5410.5410.5410.5410.5410.5410.54
Safety Valve Set Pressurekg / cm2(g)10.5410.5410.5410.5410.5410.5410.54
Hydrotest Pressurekg / cm2(g)15.8115.8115.8115.8115.8115.8115.81
Steam Temperature (Max)0 C185185185185185185185
Dryness Fraction%88888888888888
Boiler FuelDIESELDIESELDIESELDIESELDIESELDIESELDIESEL
Fuel NCVkcal/kg10200102001020010200102001020010200
Heat OutputMW0.060.130.190.250.310.380.53
Heating Surfacem23.53.54.54.55.95.97.1
Thermal Efficiency%90+/-2%90+/-2%90+/-2%90+/-2%90+/-2%90+/-2%90+/-2%
BOILER MOC & CONSTRUCTION
Stress RelivingAs per ASMEAs per ASMEAs per ASMEAs per ASMEAs per ASMEAs per ASMEAs per ASME
Type of FurnaceIntegralIntegralIntegralIntegralIntegralIntegralIntegral
No of FurnaceOneOneOneOneOneOneOne
Boiler Shell, furnace & tube plateSA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70
Plain TubeBS 3059 ERW 320BS 3059 ERW 320BS 3059 ERW 320BS 3059 ERW 320BS 3059 ERW 320BS 3059 ERW 320BS 3059 ERW 320
Stay TubesBS 3059 ERW 360BS 3059 ERW 360BS 3059 ERW 360BS 3059 ERW 360BS 3059 ERW 360BS 3059 ERW 360BS 3059 ERW 360
Pads & BossesSA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70SA 516 Gr 70
Stand PipesSA 106 Gr BSA 106 Gr BSA 106 Gr BSA 106 Gr BSA 106 Gr BSA 106 Gr BSA 106 Gr B
BOILER BURNER SPECIFICATION
Burner ConstructionTwo StageTwo StageTwo StageTwo StageTwo StageTwo StageTwo Stage
Burner ControllerServoMeterServoMeterServoMeterServoMeterServoMeterServoMeterServoMeter
Turn down ration1:'51:'51:'51:'51:'51:'51:'5
Flame detection by photoresistanceProvidedProvidedProvidedProvidedProvidedProvidedProvided
Electric protection ratingIP 40IP 40IP 40IP 40IP 40IP 40IP 40
BOILER FUEL CONSUMPTION
DIESELKg/hr6.0212.0318.0524.0630.0836.1051.14
DIMENSIONS & WEIGHT
Overall Lengthm1.11.31.51.51.51.51.75
Overall Widthm0.851.11.31.31.41.41.75
Overall Heightm1.11.7222.32.33
Dry Weightkg60080010001000110011001600
Flue gas outlet dia.mm100150200200250250250

Our Technology

Explore Avlon Inc’s comprehensive range of energy and environmental equipment, engineered to deliver reliable performance, operational efficiency, and sustainable industrial solutions across diverse applications.

Key Features

High Capacity
High Capacity
Fuel Flexibility
Fuel Flexibility
Long Life
Long Life
Efficient Combustion
Efficient Combustion
Heavy Duty
Heavy Duty

Reach Out to Us

Connect with our experts to discuss your project requirements & discover customized environmental and engineering solutions tailored to your needs.

Download Catalogue

Explore our complete range of products and solutions, including detailed specifications & features designed to meet diverse industry.

Solutions Within...!! Delivering Clean Water, Clean Air, & Reliable Energy Solutions

Connect with Avlon Inc for reliable energy and environmental engineering solutions designed to improve efficiency, ensure compliance, and support your long-term growth.

Request a Consultation

My Cart